What requirements should be met in the design of 2~8℃ constant temperature pharmaceutical warehouse? As a special commodity, the quality and safety of pharmaceuticals are directly related to the life and health of patients. Therefore, in the storage process of pharmaceuticals, it is crucial to ensure the constant temperature and humidity of the storage environment. Especially in the design of pharmaceutical warehouses that need to be stored at 2~8℃, a series of design requirements need to be strictly followed to ensure the quality and safety of pharmaceuticals during storage.
When designing a 2~8℃ constant temperature pharmaceutical warehouse, the first thing to be clear is the temperature range of the warehouse. This temperature range is determined based on the storage needs of a large number of pharmaceuticals and is suitable for most pharmaceuticals that require refrigeration, such as biological products, vaccines, blood products, etc. In order to ensure that the temperature in the warehouse is always kept within the set range, an efficient and reliable refrigeration system needs to be selected. The refrigeration equipment should adopt the form of one standby and one use, in accordance with the GSP (Good Manufacturing Practice for Pharmaceuticals) and GMP (Good Manufacturing Practice for Pharmaceuticals) certification specifications. When one of the units stops working due to a fault, it automatically switches to the standby unit to operate, thereby ensuring that the temperature control in the warehouse is not affected.
The selection of insulation materials is also an important part of the design. In order to reduce energy consumption and maintain a stable temperature in the warehouse, insulation materials with strong insulation performance, convenient installation and good flame retardant effect should be selected. Polyurethane double-sided color steel plate is one of the commonly used insulation materials on the market, and its thickness should be determined according to the specific temperature requirements and insulation requirements of the warehouse. Under normal circumstances, a 10-centimeter-thick polyurethane double-sided color steel plate can achieve the ideal insulation effect for a pharmaceutical warehouse with a temperature of 2~8℃.
In addition to temperature and insulation design, pharmaceutical warehouses also need to be equipped with a complete temperature and humidity monitoring and control system. This system should include automatic temperature monitoring, display, recording, control and alarm equipment, which can monitor the temperature and humidity in the warehouse in real time and automatically alarm when the temperature or humidity exceeds the set range. The recording interval should not exceed 30 minutes to ensure that warehouse managers can detect and deal with abnormal situations in time. At the same time, the warehouse should be equipped with sufficient lighting and ventilation equipment to keep the air circulation and light in the warehouse sufficient.
In the layout and design of the warehouse, it is also necessary to consider the classification and clear identification of drugs. Different types of drugs should be stored in different areas and clearly marked to facilitate managers to quickly and accurately find the required drugs. In addition, reasonable passages and stacking spaces should be set up in the warehouse to facilitate the handling and storage of medicines.
During the construction of the warehouse, a series of national and industry standards and specifications need to be followed. For example, “Technical Specifications for Verification and Performance Confirmation of Temperature Control Facilities and Equipment for Cold Chain Logistics of Pharmaceutical Products”, “Construction and Acceptance Specifications for Installation of Refrigeration Equipment and Air Separation Equipment”, etc. These standards and specifications provide clear guidance and basis for the design, construction and acceptance of pharmaceutical warehouses.
In summary, the design requirements of 2~8℃ constant temperature pharmaceutical warehouses cover temperature control, insulation material selection, temperature and humidity monitoring and control systems, warehouse layout and classified storage, etc. Only by strictly designing and constructing in accordance with these requirements can the quality and safety of drugs during storage be ensured, and high-quality medical services can be provided to patients.
If you are not very familiar with the design requirements of 2~8℃ constant temperature pharmaceutical warehouses, HAOCOOL provides free cold storage design solutions and cold storage project quotation detailed lists, professionally provides a complete set of cold storage project design, equipment, installation, and after-sales integrated solutions, and provides cold storage construction services for large food, pharmaceutical, cold chain logistics, chemical and other enterprises.